Perforated Panel Acoustics

Effect of flow resistivity

Plasterboard 6 mm Round (Reversed), No MLV

Insulation comparisons keyed on measured airflow resistivity.

Tests

2

first: GW 90 mm R2.5 (17,100 N·s/m⁴)

Rw range

14–19dB

spread 5 dB

Highest Rw

19dB

GW 90 mm R2.7 (26,400 N·s/m⁴)

Largest ΔRw vs first

+5dB

GW 90 mm R2.7 (26,400 N·s/m⁴)

Sound reduction index (R)

R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture (the opening with nothing in it) and unperforated 10 mm plasterboard.

Single-number ratings

Open in explorer
ListenVariesRwCCtrΔRw vs firstΔRw vs openMean R
GW 90 mm R2.5 (17,100 N·s/m⁴)
14
0−3ref.+1413.1
GW 90 mm R2.7 (26,400 N·s/m⁴)
19
−1−3+5+1919.2

Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.