Tests
4
first: PB 6 mm Round (No Scrim) (10.4%)
Rw range
3–7dB
spread 4 dB
Highest Rw
7dB
PB 12 mm Round (17.7%)
Largest ΔRw vs first
+2dB
PB 12 mm Round (17.7%)
Sound reduction index (R)
R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture (the opening with nothing in it) and unperforated 10 mm plasterboard.
Single-number ratings
Open in explorer- PB 6 mm Round (No Scrim) (10.4%)C 0 · Ctr −1 · vs open +5 · mean R 4.15 dBfirst
- PB 12 mm Round (17.7%)C 0 · Ctr 0 · vs open +7 · mean R 8.37 dB+2
- PB 12 mm Round (No Scrim) (17.7%)C 0 · Ctr 0 · vs open +3 · mean R 3.03 dB−2
- PB 15 mm Round (19.6%)C 0 · Ctr 0 · vs open +7 · mean R 7.47 dB+2
| Listen | Varies | Rw | C | Ctr | ΔRw vs first | ΔRw vs open | Mean R | |
|---|---|---|---|---|---|---|---|---|
| PB 6 mm Round (No Scrim) (10.4%) | 5 | 0 | −1 | ref. | +5 | 4.1 | ||
| PB 12 mm Round (17.7%) | 7 | 0 | 0 | +2 | +7 | 8.3 | ||
| PB 12 mm Round (No Scrim) (17.7%) | 3 | 0 | 0 | −2 | +3 | 3.0 | ||
| PB 15 mm Round (19.6%) | 7 | 0 | 0 | +2 | +7 | 7.4 |
Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.