Perforated Panel Acoustics

Effect of hole shape

Plasterboard, Glass Wool 90 mm R2.5, No MLV

Same material, insulation and MLV, perforation geometry varied.

Tests

5

first: PB 6 mm Round (No Scrim) (10.4%)

Rw range

14–20dB

spread 6 dB

Highest Rw

20dB

PB 12 mm Hexagon (23.4%)

Largest ΔRw vs first

+6dB

PB Slots (13.1%)

Sound reduction index (R)

R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture (the opening with nothing in it) and unperforated 10 mm plasterboard.

Single-number ratings

Open in explorer
ListenVariesRwCCtrΔRw vs firstΔRw vs openMean R
PB 6 mm Round (No Scrim) (10.4%)
14
0−2ref.+1413.5
PB 12 mm Round (17.7%)
19
0−2+5+1917.4
PB 15 mm Round (19.6%)
19
−1−3+4+1816.6
PB 12 mm Hexagon (23.4%)
20
−1−3+5+1917.5
PB Slots (13.1%)
20
0−2+6+2018.4

Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.