Perforated Panel Acoustics

Effect of insulation

Plasterboard 12 mm Square, No MLV

Same panel and MLV state, insulation product varied.

Tests

2

first: No Insulation

Rw range

7–13dB

spread 6 dB

Highest Rw

13dB

GW 45 mm R2.5

Largest ΔRw vs first

+6dB

GW 45 mm R2.5

Sound reduction index (R)

R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture (the opening with nothing in it) and unperforated 10 mm plasterboard.

Single-number ratings

Open in explorer
ListenVariesRwCCtrΔRw vs firstΔRw vs openMean R
No Insulation
7
00ref.+77.6
GW 45 mm R2.5
13
0−1+6+1312.3

Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.