Effect of insulation
Sheet Metal 2.38 mm Round, No MLV
Same panel and MLV state, insulation product varied.
Tests
4
first: No Insulation
Rw range
1–17dB
spread 16 dB
Highest Rw
17dB
GW 90 mm R2.7
Largest ΔRw vs first
+16dB
GW 90 mm R2.7
Sound reduction index (R)
R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture (the opening with nothing in it) and unperforated 10 mm plasterboard.
Single-number ratings
Open in explorer- No InsulationC 0 · Ctr 0 · vs open +1 · mean R 1.21 dBfirst
- GW 45 mm R2.5C 0 · Ctr −1 · vs open +7 · mean R 6.07 dB+6
- GW 90 mm R2.5C −1 · Ctr −2 · vs open +12 · mean R 10.412 dB+11
- GW 90 mm R2.7C 0 · Ctr −3 · vs open +17 · mean R 16.417 dB+16
| Listen | Varies | Rw | C | Ctr | ΔRw vs first | ΔRw vs open | Mean R | |
|---|---|---|---|---|---|---|---|---|
| No Insulation | 1 | 0 | 0 | ref. | +1 | 1.2 | ||
| GW 45 mm R2.5 | 7 | 0 | −1 | +6 | +7 | 6.0 | ||
| GW 90 mm R2.5 | 12 | −1 | −2 | +11 | +12 | 10.4 | ||
| GW 90 mm R2.7 | 17 | 0 | −3 | +16 | +17 | 16.4 |
Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.