Effect of orientation
Plasterboard 6 mm Round, Glass Wool 90 mm R2.5, MLV
Assembly turned around in the opening: plaster facing source or receiver.
Tests
2
first: PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source)
Rw range
29–30dB
spread 1 dB
Highest Rw
30dB
PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source)
Largest ΔRw vs first
−1dB
PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver)
Sound reduction index (R)
R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture (the opening with nothing in it) and unperforated 10 mm plasterboard.
Single-number ratings
Open in explorer- PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source)C −2 · Ctr −6 · vs open +29 · mean R 28.230 dBfirst
- PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver)C −2 · Ctr −6 · vs open +28 · mean R 25.229 dB−1
| Listen | Varies | Rw | C | Ctr | ΔRw vs first | ΔRw vs open | Mean R | |
|---|---|---|---|---|---|---|---|---|
| PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source) | 30 | −2 | −6 | ref. | +29 | 28.2 | ||
| PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver) | 29 | −2 | −6 | −1 | +28 | 25.2 |
Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.