Repeatability
Plasterboard Non-Perforated (10 mm), No Insulation, No MLV
The same build measured twice on different days.
Tests
2
first: 25 Aug 2026 (Project069)
Rw range
23–24dB
spread 1 dB
Highest Rw
24dB
22 Sep 2026 (Project074)
Largest ΔRw vs first
+1dB
22 Sep 2026 (Project074)
Sound reduction index (R)
R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey line: the open aperture (the opening with nothing in it).
Single-number ratings
Open in explorer- 25 Aug 2026 (Project069)C −1 · Ctr −1 · vs open +23 · mean R 20.823 dBfirst
- 22 Sep 2026 (Project074)C 0 · Ctr −1 · vs open +24 · mean R 22.224 dB+1
| Listen | Varies | Rw | C | Ctr | ΔRw vs first | ΔRw vs open | Mean R | |
|---|---|---|---|---|---|---|---|---|
| 25 Aug 2026 (Project069) | 23 | −1 | −1 | ref. | +23 | 20.8 | ||
| 22 Sep 2026 (Project074) | 24 | 0 | −1 | +1 | +24 | 22.2 |
Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.