No Panel, No MLV

Insulation sweeps keyed on measured airflow resistivity.

Tests

7

Effect of Insulation Flow Resistivity

Rw range

7–18dB

spread 11 dB

Highest Rw

18dB

Polyester (1,800 N·s/m⁴)

Largest ΔRw vs first

−12dB

GW 45 mm R2.5 (12,000 N·s/m⁴)

Sound reduction index

R′ from the 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB). Grey lines: reference bounds.

Single-number ratings

Open in explorer
VariesTestRwCCtrΔRw vs firstΔRw vs openMean R
Polyester (1,800 N·s/m⁴)Project055
18
0−1ref.+1816.7
GW 210 mm R5 (8,500 N·s/m⁴)Project049
17
−1−4±0+1614.3
GW 100 mm R5 (8,800 N·s/m⁴)Project051
8
0−1−10+87.0
GW 175 mm R3.5 (9,500 N·s/m⁴)Project050
11
0−2−7+119.2
GW 45 mm R2.5 (12,000 N·s/m⁴)Project052
7
−1−2−12+65.7
GW 90 mm R2.5 (15,000 N·s/m⁴)Project048
12
−1−2−6+1210.2
GW 90 mm R2.7 (34,000 N·s/m⁴)Project047
17
0−3+1+1716.2

Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to the band-by-band difference curve, which is not the same number as subtracting two separately rounded Rw values. Mean R is the arithmetic mean over the 16 rating bands.