Plasterboard 15 mm Round, No MLV

Insulation sweeps keyed on measured airflow resistivity.

Tests

5

Effect of Insulation Flow Resistivity

Rw range

7–23dB

spread 16 dB

Highest Rw

23dB

GW 90 mm R2.7 (34,000 N·s/m⁴)

Largest ΔRw vs first

+17dB

GW 90 mm R2.7 (34,000 N·s/m⁴)

Sound reduction index

R′ from the 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB). Grey lines: reference bounds.

Single-number ratings

Open in explorer
VariesTestRwCCtrΔRw vs firstΔRw vs openMean R
No InsulationProject013
7
00ref.+77.4
GW 100 mm R5 (8,800 N·s/m⁴)Project017
16
−1−2+9+1513.8
GW 45 mm R2.5 (12,000 N·s/m⁴)Project015
13
0−1+7+1312.0
GW 90 mm R2.5 (15,000 N·s/m⁴)Project018
19
−1−3+12+1816.6
GW 90 mm R2.7 (34,000 N·s/m⁴)Project016
23
0−3+17+2322.2

Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to the band-by-band difference curve, which is not the same number as subtracting two separately rounded Rw values. Mean R is the arithmetic mean over the 16 rating bands.