Plasterboard 6 mm Round, No MLV

Insulation sweeps keyed on measured airflow resistivity.

Tests

6

Effect of Insulation Flow Resistivity

Rw range

5–19dB

spread 14 dB

Highest Rw

19dB

GW 90 mm R2.7 (34,000 N·s/m⁴)

Largest ΔRw vs first

+16dB

GW 90 mm R2.7 (34,000 N·s/m⁴)

Sound reduction index

R′ from the 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB). Grey lines: reference bounds.

Single-number ratings

Open in explorer
VariesTestRwCCtrΔRw vs firstΔRw vs openMean R
No InsulationProject004
5
0−1ref.+54.1
GW 100 mm R5 (8,800 N·s/m⁴)Project005
12
−1−3+8+1110.3
GW 175 mm R3.5 (9,500 N·s/m⁴)Project008
14
0−3+11+1412.6
GW 45 mm R2.5 (12,000 N·s/m⁴)Project007
10
0−2+7+109.0
GW 90 mm R2.5 (15,000 N·s/m⁴)Project006
14
0−2+11+1413.5
GW 90 mm R2.7 (34,000 N·s/m⁴)Project009
19
−1−4+16+1818.9

Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to the band-by-band difference curve, which is not the same number as subtracting two separately rounded Rw values. Mean R is the arithmetic mean over the 16 rating bands.