Plasterboard 6 mm Round, Glass Wool 90 mm R2.5, No MLV

Assembly turned around in the opening: plaster facing source or receiver.

Tests

2

Effect of Orientation

Rw range

14dB

spread 0 dB

Highest Rw

14dB

PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source)

Largest ΔRw vs first

±0dB

PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver)

Sound reduction index

R′ from the 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB). Grey lines: reference bounds.

Single-number ratings

Open in explorer
VariesTestRwCCtrΔRw vs firstΔRw vs openMean R
PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source)Project006
14
0−2ref.+1413.5
PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver)Project064
14
0−3±0+1413.1

Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to the band-by-band difference curve, which is not the same number as subtracting two separately rounded Rw values. Mean R is the arithmetic mean over the 16 rating bands.