Plasterboard Non-Perforated (10 mm), No Insulation, No MLV

The same build measured twice on different days.

Tests

2

Repeat Test

Rw range

23–24dB

spread 1 dB

Highest Rw

24dB

22 Sep 2026 (Project074)

Largest ΔRw vs first

+2dB

22 Sep 2026 (Project074)

Sound reduction index

R′ from the 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB). Grey lines: reference bounds.

Single-number ratings

Open in explorer
VariesTestRwCCtrΔRw vs firstΔRw vs openMean R
25 Aug 2026 (Project069)Project069
23
−1−1ref.+2320.8
22 Sep 2026 (Project074)Project074
24
0−1+2+2422.2

Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to the band-by-band difference curve, which is not the same number as subtracting two separately rounded Rw values. Mean R is the arithmetic mean over the 16 rating bands.