Perforated Panel Acoustics

Open aperture

Open Aperture · No Insulation · No MLV

Tested 7 July 2026

Rw (C; Ctr)

0dB

C 0 · Ctr 0

ΔRw vs open

–

This is the baseline

Mean R

0.8dB

100–3150 Hz

Rank by Rw

64of 64

No ties

Sound reduction index (R)

ISO 717-1: reference curve shifted to Rw 0 dB; Σ unfavourable deviations 25.0 dB ≤ 32 dB (bars).

R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey line: the solid PB 10 mm, for scale.

Receiving-room reverberation time (T60)

The B&K 2270's T20 Room row, extrapolated to 60 dB. Axis cropped at 15 s; the band table lists every value. Grey lines: the empty room and solid PB 10 mm, for scale.

Sabine absorption of the specimen (αs)

ISO 354 difference method with the empty receiving room as baseline, so αs is the absorption the specimen adds to the room. V = 180 m³, S = 0.9216 m². Shown over the ISO 354 range 100 Hz–5 kHz only. Axis cropped at αs = 2; the band table lists every value.

Specification

Schematic. Dashed outline: where a panel would sit.

Panel

Panel
None: open aperture

Insulation

Insulation
None

Mass-loaded vinyl

MLV
No

Test

Tested
7 July 2026
Matrix group
Baseline

Band values

HzRRef.Dev.T60αs
50–––
632.013.32–
800.98.64–
1002.8-190.06.161.01
1253.6-160.06.260.78
1601.8-130.06.850.70
2001.3-100.05.570.72
2501.1-70.05.110.74
3150.8-40.04.850.79
4000.3-10.04.630.53
5000.100.04.930.73
6300.110.84.810.86
8000.121.94.730.89
1k0.133.04.230.88
1.25k0.143.93.860.83
1.6k0.143.93.590.86
2k0.144.03.221.05
2.5k0.143.92.921.15
3.15k0.343.82.611.28
4k0.72.241.56
5k0.11.762.22
6.3k0.11.39–
8k0.91.09–
10k1.80.88–
Σ25.0

R, Ref. and Dev. in dB, T60 in s. Ref. is the ISO 717-1 reference curve shifted to Rw 0 dB; Dev. is how far R falls below it, and the deviations may total at most 32 dB. αs over 100 Hz–5 kHz only.

Open in explorer