Perforated Panel Acoustics

MDF

Solid MDF Panel · No Insulation · No MLV

Tested 3 July 2026

Rw (C; Ctr)

27dB

C −1 · Ctr 0

ΔRw vs open

+27dB

Fit to R − R(open aperture)

Mean R

26.3dB

100–3150 Hz

Rank by Rw

11of 64

No ties

Sound reduction index (R)

ISO 717-1: reference curve shifted to Rw 27 dB; Σ unfavourable deviations 24.2 dB ≤ 32 dB (bars).

R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture and solid PB 10 mm, for scale.

Receiving-room reverberation time (T60)

The B&K 2270's T20 Room row, extrapolated to 60 dB. Axis cropped at 15 s; the band table lists every value. Grey lines: the empty room and solid PB 10 mm, for scale.

Sabine absorption of the specimen (αs)

ISO 354 difference method with the empty receiving room as baseline, so αs is the absorption the specimen adds to the room. V = 180 m³, S = 0.9216 m². Shown over the ISO 354 range 100 Hz–5 kHz only. Axis cropped at αs = 2; the band table lists every value.

Specification

Schematic.

Panel

Panel
Solid MDF Panel
Perforation
None
Open area
–
Panel thickness
10 mm
Scrim
–
Orientation
Standard

Insulation

Insulation
None

Mass-loaded vinyl

MLV
No

Test

Tested
3 July 2026
Matrix group
Baseline

Band values

HzRRef.Dev.T60αs
5034.025.57–
6319.813.59–
8019.610.34–
10023.180.08.23−0.27
12526.1110.07.090.19
16025.4140.07.480.32
20023.4170.06.230.12
25025.3200.05.82−0.01
31526.1230.05.400.13
40025.9260.15.05−0.04
50026.4270.65.460.11
63027.6280.45.480.06
80028.6290.45.340.13
1k29.4300.64.740.08
1.25k29.4311.64.190.19
1.6k27.4313.63.870.23
2k22.6318.43.440.43
2.5k24.9316.13.140.40
3.15k28.9312.12.860.23
4k33.02.440.41
5k34.51.970.32
6.3k36.61.57–
8k39.01.23–
10k41.51.02–
Σ24.2

R, Ref. and Dev. in dB, T60 in s. Ref. is the ISO 717-1 reference curve shifted to Rw 27 dB; Dev. is how far R falls below it, and the deviations may total at most 32 dB. αs over 100 Hz–5 kHz only.