Perforated Panel Acoustics

Effect of panel type

All Panels, No Insulation, No MLV

Every bare panel, no insulation, no MLV.

Tests

12

first: PB 6 mm Round (No Scrim) (10.4%)

Rw range

1–29dB

spread 28 dB

Highest Rw

29dB

PB solid (13 mm) (0.0%)

Largest ΔRw vs first

+24dB

PB solid (13 mm) (0.0%)

Sound reduction index (R)

R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey line: the open aperture (the opening with nothing in it). Past eight series, colours repeat with a dash pattern.

Single-number ratings

Open in explorer
ListenVariesRwCCtrΔRw vs firstΔRw vs openMean R
PB 6 mm Round (No Scrim) (10.4%)
5
0−1ref.+54.1
PB 12 mm Round (17.7%)
7
00+2+78.3
PB 12 mm Round (No Scrim) (17.7%)
3
00−2+33.0
PB 15 mm Round (19.6%)
7
00+2+77.4
PB 12 mm Square (22.6%)
7
00+2+77.6
PB 12 mm Hexagon (23.4%)
8
00+3+88.6
PB Slots (13.1%)
9
00+3+89.1
PB solid (10 mm) (0.0%)
23
−1−1+18+2320.8
PB solid (13 mm) (0.0%)
29
−1−1+24+2926.9
PB solid (10 mm) (0.0%)
25
0−2+20+2522.5
SM 1.6 mm Round (23.0%)
1
00−4+11.0
SM 2.38 mm Round (11.0%)
1
00−4+11.2

Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.