PB Slots
Plasterboard Slots · No Insulation · No MLV
Tested 10 July 2026
Rw (C; Ctr)
9dB
C 0 · Ctr 0
ΔRw vs open
+8dB
Fit to R − R(open aperture)
Mean R
9.1dB
100–3150 Hz
Rank by Rw
50of 64
No ties
Specification
Panel
- Panel
- Plasterboard Slots
- Perforation
- Slots
- Open area
- 13.1 %
- Panel thickness
- 12.9 mm
- Scrim
- Yes
- Orientation
- Standard
Insulation
- Insulation
- None
Mass-loaded vinyl
- MLV
- No
Test
- Tested
- 10 July 2026
- Matrix group
- Baseline
Band values
| Hz | R | Ref. | Dev. | T60 | αs |
|---|---|---|---|---|---|
| 50 | – | – | – | ||
| 63 | 15.3 | 16.23 | – | ||
| 80 | 10.3 | 7.75 | – | ||
| 100 | 12.8 | -10 | 0.0 | 7.04 | 0.37 |
| 125 | 12.8 | -7 | 0.0 | 6.17 | 0.85 |
| 160 | 10.1 | -4 | 0.0 | 6.42 | 1.01 |
| 200 | 8.9 | -1 | 0.0 | 5.38 | 0.92 |
| 250 | 8.8 | 2 | 0.0 | 5.03 | 0.84 |
| 315 | 8.3 | 5 | 0.0 | 4.78 | 0.88 |
| 400 | 7.8 | 8 | 0.2 | 4.48 | 0.76 |
| 500 | 7.7 | 9 | 1.3 | 4.89 | 0.79 |
| 630 | 7.8 | 10 | 2.3 | 4.81 | 0.86 |
| 800 | 8.1 | 11 | 2.9 | 4.83 | 0.75 |
| 1k | 8.6 | 12 | 3.4 | 4.36 | 0.66 |
| 1.25k | 8.8 | 13 | 4.3 | 3.98 | 0.59 |
| 1.6k | 8.8 | 13 | 4.3 | 3.72 | 0.55 |
| 2k | 8.9 | 13 | 4.1 | 3.35 | 0.68 |
| 2.5k | 9.2 | 13 | 3.8 | 3.07 | 0.63 |
| 3.15k | 8.8 | 13 | 4.2 | 2.73 | 0.75 |
| 4k | 9.3 | 2.35 | 0.90 | ||
| 5k | 8.9 | 1.86 | 1.26 | ||
| 6.3k | 9.3 | 1.49 | – | ||
| 8k | 10.2 | 1.15 | – | ||
| 10k | 10.8 | 0.92 | – | ||
| Σ | 30.7 |
R, Ref. and Dev. in dB, T60 in s. Ref. is the ISO 717-1 reference curve shifted to Rw 9 dB; Dev. is how far R falls below it, and the deviations may total at most 32 dB. αs over 100 Hz–5 kHz only.
In comparisons5
Sets of tests that differ from this one in a single variable.
Effect of insulation
Plasterboard Slots, No MLV
This testNo InsulationRw rank6 of 6
Effect of hole shape
Plasterboard, No Insulation, No MLV
This testPB Slots (13.1%)Rw rank4 of 10
Effect of panel type
All Panels, No Insulation, No MLV
This testPB Slots (13.1%)Rw rank4 of 12
Effect of flow resistivity
Plasterboard Slots, No MLV
This testNo InsulationRw rank6 of 6
Effect of open area
Plasterboard, No Insulation, No MLV
This testPB Slots (13.1%)Rw rank4 of 10