Tests
3
first: No Insulation
Rw range
23–34dB
spread 11 dB
Highest Rw
34dB
GW 90 mm R2.7
Largest ΔRw vs first
+10dB
GW 90 mm R2.7
Sound reduction index (R)
R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey line: the open aperture (the opening with nothing in it).
Single-number ratings
Open in explorer- No InsulationC −1 · Ctr −1 · vs open +23 · mean R 20.823 dBfirst
- No InsulationC 0 · Ctr −2 · vs open +25 · mean R 22.525 dB+2
- GW 90 mm R2.7C −2 · Ctr −6 · vs open +33 · mean R 32.034 dB+10
| Listen | Varies | Rw | C | Ctr | ΔRw vs first | ΔRw vs open | Mean R | |
|---|---|---|---|---|---|---|---|---|
| No Insulation | 23 | −1 | −1 | ref. | +23 | 20.8 | ||
| No Insulation | 25 | 0 | −2 | +2 | +25 | 22.5 | ||
| GW 90 mm R2.7 | 34 | −2 | −6 | +10 | +33 | 32.0 |
Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.