Perforated Panel Acoustics

Effect of insulation

Plasterboard Non-Perforated (10 mm), No MLV

Same panel and MLV state, insulation product varied.

Tests

3

first: No Insulation

Rw range

23–34dB

spread 11 dB

Highest Rw

34dB

GW 90 mm R2.7

Largest ΔRw vs first

+10dB

GW 90 mm R2.7

Sound reduction index (R)

R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey line: the open aperture (the opening with nothing in it).

Single-number ratings

Open in explorer
ListenVariesRwCCtrΔRw vs firstΔRw vs openMean R
No Insulation
23
−1−1ref.+2320.8
No Insulation
25
0−2+2+2522.5
GW 90 mm R2.7
34
−2−6+10+3332.0

Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.