Tests
6
first: No Insulation
Rw range
5–19dB
spread 14 dB
Highest Rw
19dB
GW 90 mm R2.7
Largest ΔRw vs first
+13dB
GW 90 mm R2.7
Sound reduction index (R)
R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture (the opening with nothing in it) and unperforated 10 mm plasterboard.
Single-number ratings
Open in explorer- No InsulationC 0 · Ctr −1 · vs open +5 · mean R 4.15 dBfirst
- GW 45 mm R2.5C 0 · Ctr −2 · vs open +10 · mean R 9.010 dB+5
- GW 90 mm R2.5C 0 · Ctr −2 · vs open +14 · mean R 13.514 dB+9
- GW 90 mm R2.7C −1 · Ctr −4 · vs open +18 · mean R 18.919 dB+13
- GW 100 mm R5C −1 · Ctr −3 · vs open +11 · mean R 10.312 dB+6
- GW 175 mm R3.5C 0 · Ctr −3 · vs open +14 · mean R 12.614 dB+9
| Listen | Varies | Rw | C | Ctr | ΔRw vs first | ΔRw vs open | Mean R | |
|---|---|---|---|---|---|---|---|---|
| No Insulation | 5 | 0 | −1 | ref. | +5 | 4.1 | ||
| GW 45 mm R2.5 | 10 | 0 | −2 | +5 | +10 | 9.0 | ||
| GW 90 mm R2.5 | 14 | 0 | −2 | +9 | +14 | 13.5 | ||
| GW 90 mm R2.7 | 19 | −1 | −4 | +13 | +18 | 18.9 | ||
| GW 100 mm R5 | 12 | −1 | −3 | +6 | +11 | 10.3 | ||
| GW 175 mm R3.5 | 14 | 0 | −3 | +9 | +14 | 12.6 |
Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.