Tests
4
first: PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source, No MLV)
Rw range
14–30dB
spread 16 dB
Highest Rw
30dB
PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source, MLV)
Largest ΔRw vs first
+15dB
PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source, MLV)
Sound reduction index (R)
R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture (the opening with nothing in it) and unperforated 10 mm plasterboard.
Single-number ratings
Open in explorer- PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source, No MLV)C 0 · Ctr −2 · vs open +14 · mean R 13.514 dBfirst
- PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source, MLV)C −2 · Ctr −6 · vs open +29 · mean R 28.230 dB+15
- PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver, No MLV)C 0 · Ctr −3 · vs open +14 · mean R 13.114 dB±0
- PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver, MLV)C −2 · Ctr −6 · vs open +28 · mean R 25.229 dB+14
| Listen | Varies | Rw | C | Ctr | ΔRw vs first | ΔRw vs open | Mean R | |
|---|---|---|---|---|---|---|---|---|
| PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source, No MLV) | 14 | 0 | −2 | ref. | +14 | 13.5 | ||
| PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source, MLV) | 30 | −2 | −6 | +15 | +29 | 28.2 | ||
| PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver, No MLV) | 14 | 0 | −3 | ±0 | +14 | 13.1 | ||
| PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver, MLV) | 29 | −2 | −6 | +14 | +28 | 25.2 |
Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.