Tests
2
first: PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source)
Rw range
19dB
spread 0 dB
Highest Rw
19dB
PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source)
Largest ΔRw vs first
+1dB
PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver)
Sound reduction index (R)
R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture (the opening with nothing in it) and unperforated 10 mm plasterboard.
Single-number ratings
Open in explorer- PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source)C −1 · Ctr −4 · vs open +18 · mean R 18.919 dBfirst
- PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver)C −1 · Ctr −3 · vs open +19 · mean R 19.219 dB+1
| Listen | Varies | Rw | C | Ctr | ΔRw vs first | ΔRw vs open | Mean R | |
|---|---|---|---|---|---|---|---|---|
| PB 6 mm Round (No Scrim) (10.4%) (Plaster facing source) | 19 | −1 | −4 | ref. | +18 | 18.9 | ||
| PB 6 mm Round (No Scrim) (10.4%) (Plaster facing receiver) | 19 | −1 | −3 | +1 | +19 | 19.2 |
Right: Rw, and below it ΔRw against the first test. Rw, C and Ctr per ISO 717-1 over 100–3150 Hz. ΔRw fits the reference curve to R − R(open aperture); ΔRw vs first is the difference between a test's ΔRw and the first test's, as the report quotes changes, so it can differ by a decibel from the change in Rw. Mean R is the arithmetic mean over the 16 rating bands.