Perforated Panel Acoustics

PB 6 mm Round (no scrim) + GW 45 mm R2.5

Plasterboard 6 mm Round · Glass Wool 45 mm R2.5 · No MLV

Tested 7 July 2026

Rw (C; Ctr)

10dB

C 0 · Ctr −2

ΔRw vs open

+10dB

Fit to R − R(open aperture)

Mean R

9.0dB

100–3150 Hz

Rank by Rw

49of 64

No ties

Sound reduction index (R)

ISO 717-1: reference curve shifted to Rw 10 dB; Σ unfavourable deviations 26.5 dB ≤ 32 dB (bars).

R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture and solid PB 10 mm, for scale.

Receiving-room reverberation time (T60)

The B&K 2270's T20 Room row, extrapolated to 60 dB. Axis cropped at 15 s; the band table lists every value. Grey lines: the empty room and solid PB 10 mm, for scale.

Sabine absorption of the specimen (αs)

ISO 354 difference method with the empty receiving room as baseline, so αs is the absorption the specimen adds to the room. V = 180 m³, S = 0.9216 m². Shown over the ISO 354 range 100 Hz–5 kHz only. Axis cropped at αs = 2; the band table lists every value.

Specification

Schematic. Insulation depth to scale. Holes enlarged, at the board's open area.

Panel

Panel
Plasterboard 6 mm Round
Perforation
Round, Ø6 mm
Open area
10.4 %
Panel thickness
12.9 mm
Scrim
No
Orientation
Standard

Insulation

Insulation
Glass wool
Thickness
45 mm
Thermal R-value
R2.5
Flow resistivity σ
14.8k N·s/m⁴measured 11.1k–19.2k
Flow resistance σ·d
666 N·s/m³

Mass-loaded vinyl

MLV
No

Test

Tested
7 July 2026
Matrix group
Impact on Hole Shape & Other Variables

Band values

HzRRef.Dev.T60αs
5023.622.38–
637.513.89–
804.78.19–
1007.7-90.06.550.71
1258.2-60.06.140.88
1605.5-30.06.570.90
2004.300.05.390.91
2504.330.04.891.02
3154.361.84.601.14
4004.394.84.291.07
5004.8105.34.521.31
6306.3114.84.481.34
8008.0124.04.411.37
1k9.7133.33.951.41
1.25k11.8142.33.661.28
1.6k13.7140.33.431.27
2k15.3140.03.091.47
2.5k17.4140.02.841.46
3.15k19.1140.02.571.47
4k21.42.211.75
5k22.41.762.22
6.3k22.81.42–
8k22.61.11–
10k19.90.89–
Σ26.5

R, Ref. and Dev. in dB, T60 in s. Ref. is the ISO 717-1 reference curve shifted to Rw 10 dB; Dev. is how far R falls below it, and the deviations may total at most 32 dB. αs over 100 Hz–5 kHz only.

In comparisons5

Sets of tests that differ from this one in a single variable.

Open in explorer