Perforated Panel Acoustics

No Panel + GW 90 mm R2.7

No Panel · Glass Wool 90 mm R2.7 · No MLV

Tested 15 July 2026

Rw (C; Ctr)

17dB

C 0 · Ctr −3

ΔRw vs open

+17dB

Fit to R − R(open aperture)

Mean R

16.2dB

100–3150 Hz

Rank by Rw

29of 64

Tied with 5 others

Sound reduction index (R)

ISO 717-1: reference curve shifted to Rw 17 dB; Σ unfavourable deviations 25.1 dB ≤ 32 dB (bars).

R′ from the B&K 2270, re-referenced to the 0.9216 m² specimen area (−0.35 dB; −10.96 dB for the 22 Sep tests, logged with S = 11.5 m²). Grey lines: the open aperture and solid PB 10 mm, for scale.

Receiving-room reverberation time (T60)

The B&K 2270's T20 Room row, extrapolated to 60 dB. Axis cropped at 15 s; the band table lists every value. Grey lines: the empty room and solid PB 10 mm, for scale.

Sabine absorption of the specimen (αs)

ISO 354 difference method with the empty receiving room as baseline, so αs is the absorption the specimen adds to the room. V = 180 m³, S = 0.9216 m². Shown over the ISO 354 range 100 Hz–5 kHz only. Axis cropped at αs = 2; the band table lists every value.

Specification

Schematic. Insulation depth to scale. Dashed outline: where a panel would sit.

Panel

Panel
None

Insulation

Insulation
Glass wool
Thickness
90 mm
Thermal R-value
R2.7
Flow resistivity σ
26.4k N·s/m⁴measured 19.7k–33.7k
Flow resistance σ·d
2.4k N·s/m³

Mass-loaded vinyl

MLV
No

Test

Tested
15 July 2026
Matrix group
Baseline

Band values

HzRRef.Dev.T60αs
5027.825.20–
6311.413.52–
808.48.63–
10011.8-20.06.960.42
12511.710.06.200.83
1608.340.06.520.94
2007.370.05.201.12
2508.3101.84.791.15
3159.1133.94.401.45
4009.8166.24.111.39
50011.8175.34.341.60
63014.2183.84.411.45
80016.4192.64.261.62
1k18.6201.43.911.49
1.25k21.3210.03.591.45
1.6k23.8210.03.421.29
2k26.4210.03.091.47
2.5k29.4210.02.871.34
3.15k31.6210.02.591.37
4k34.32.251.50
5k36.51.831.54
6.3k39.11.47–
8k42.51.17–
10k45.00.93–
Σ25.1

R, Ref. and Dev. in dB, T60 in s. Ref. is the ISO 717-1 reference curve shifted to Rw 17 dB; Dev. is how far R falls below it, and the deviations may total at most 32 dB. αs over 100 Hz–5 kHz only.

In comparisons2

Sets of tests that differ from this one in a single variable.

Open in explorer