No Panel + GW 100 mm R5
No Panel · Glass Wool 100 mm R5 · No MLV
Tested 15 July 2026
Rw (C; Ctr)
8dB
C 0 · Ctr −1
ΔRw vs open
+8dB
Fit to R − R(open aperture)
Mean R
7.0dB
100–3150 Hz
Rank by Rw
51of 64
Tied with 1 other
Specification
Panel
- Panel
- None
Insulation
- Insulation
- Glass wool
- Thickness
- 100 mm
- Thermal R-value
- R5
- Flow resistivity σ
- 9.6k N·s/m⁴measured 9.3k–9.8k
- Flow resistance σ·d
- 957 N·s/m³
Mass-loaded vinyl
- MLV
- No
Test
- Tested
- 15 July 2026
- Matrix group
- Baseline
Band values
| Hz | R | Ref. | Dev. | T60 | αs |
|---|---|---|---|---|---|
| 50 | 23.4 | 26.40 | – | ||
| 63 | 6.8 | 14.52 | – | ||
| 80 | 4.0 | 7.91 | – | ||
| 100 | 6.7 | -11 | 0.0 | 6.18 | 0.99 |
| 125 | 7.2 | -8 | 0.0 | 5.80 | 1.18 |
| 160 | 4.5 | -5 | 0.0 | 6.29 | 1.11 |
| 200 | 3.5 | -2 | 0.0 | 5.08 | 1.26 |
| 250 | 3.9 | 1 | 0.0 | 4.70 | 1.28 |
| 315 | 4.0 | 4 | 0.0 | 4.45 | 1.37 |
| 400 | 4.0 | 7 | 3.0 | 4.14 | 1.33 |
| 500 | 4.7 | 8 | 3.3 | 4.39 | 1.52 |
| 630 | 5.8 | 9 | 3.3 | 4.40 | 1.47 |
| 800 | 6.8 | 10 | 3.3 | 4.41 | 1.37 |
| 1k | 7.5 | 11 | 3.5 | 3.98 | 1.35 |
| 1.25k | 8.7 | 12 | 3.3 | 3.63 | 1.35 |
| 1.6k | 9.7 | 12 | 2.3 | 3.43 | 1.27 |
| 2k | 10.8 | 12 | 1.3 | 3.11 | 1.40 |
| 2.5k | 12.2 | 12 | 0.0 | 2.87 | 1.34 |
| 3.15k | 13.2 | 12 | 0.0 | 2.60 | 1.32 |
| 4k | 14.3 | 2.26 | 1.44 | ||
| 5k | 14.8 | 1.83 | 1.54 | ||
| 6.3k | 15.4 | 1.47 | – | ||
| 8k | 17.1 | 1.17 | – | ||
| 10k | 18.6 | 0.93 | – | ||
| Σ | 23.3 |
R, Ref. and Dev. in dB, T60 in s. Ref. is the ISO 717-1 reference curve shifted to Rw 8 dB; Dev. is how far R falls below it, and the deviations may total at most 32 dB. αs over 100 Hz–5 kHz only.
In comparisons2
Sets of tests that differ from this one in a single variable.