No Panel + GW 175 mm R3.5
No Panel · Glass Wool 175 mm R3.5 · No MLV
Tested 15 July 2026
Rw (C; Ctr)
11dB
C 0 · Ctr −2
ΔRw vs open
+11dB
Fit to R − R(open aperture)
Mean R
9.2dB
100–3150 Hz
Rank by Rw
48of 64
No ties
Specification
Panel
- Panel
- None
Insulation
- Insulation
- Glass wool
- Thickness
- 175 mmcompressed to 100 mm in the cavity
- Thermal R-value
- R3.5
- Flow resistivity σ
- 10.2k N·s/m⁴measured 9.4k–12.3k
- Flow resistance σ·d
- 1k N·s/m³
Mass-loaded vinyl
- MLV
- No
Test
- Tested
- 15 July 2026
- Matrix group
- Baseline
Band values
| Hz | R | Ref. | Dev. | T60 | αs |
|---|---|---|---|---|---|
| 50 | – | – | – | ||
| 63 | 7.0 | 14.14 | – | ||
| 80 | 4.2 | 7.94 | – | ||
| 100 | 6.8 | -8 | 0.0 | 6.21 | 0.97 |
| 125 | 7.5 | -5 | 0.0 | 5.77 | 1.21 |
| 160 | 4.5 | -2 | 0.0 | 5.82 | 1.52 |
| 200 | 4.2 | 1 | 0.0 | 4.97 | 1.40 |
| 250 | 4.8 | 4 | 0.0 | 4.55 | 1.50 |
| 315 | 5.5 | 7 | 1.5 | 4.29 | 1.63 |
| 400 | 6.0 | 10 | 4.0 | 4.11 | 1.39 |
| 500 | 6.8 | 11 | 4.2 | 4.40 | 1.50 |
| 630 | 8.2 | 12 | 3.8 | 4.33 | 1.59 |
| 800 | 9.3 | 13 | 3.7 | 4.37 | 1.44 |
| 1k | 10.3 | 14 | 3.7 | 3.96 | 1.39 |
| 1.25k | 11.8 | 15 | 3.3 | 3.59 | 1.45 |
| 1.6k | 13.1 | 15 | 1.9 | 3.40 | 1.35 |
| 2k | 14.4 | 15 | 0.6 | 3.09 | 1.47 |
| 2.5k | 16.1 | 15 | 0.0 | 2.86 | 1.38 |
| 3.15k | 17.4 | 15 | 0.0 | 2.60 | 1.32 |
| 4k | 18.8 | 2.25 | 1.50 | ||
| 5k | 19.4 | 1.82 | 1.63 | ||
| 6.3k | 20.6 | 1.49 | – | ||
| 8k | 22.4 | 1.17 | – | ||
| 10k | 24.1 | 0.93 | – | ||
| Σ | 26.6 |
R, Ref. and Dev. in dB, T60 in s. Ref. is the ISO 717-1 reference curve shifted to Rw 11 dB; Dev. is how far R falls below it, and the deviations may total at most 32 dB. αs over 100 Hz–5 kHz only.
In comparisons2
Sets of tests that differ from this one in a single variable.