PB Slots + GW 100 mm R5
Plasterboard Slots · Glass Wool 100 mm R5 · No MLV
Tested 10 July 2026
Rw (C; Ctr)
18dB
C −1 · Ctr −3
ΔRw vs open
+17dB
Fit to R − R(open aperture)
Mean R
15.6dB
100–3150 Hz
Rank by Rw
27of 64
Tied with 1 other
Specification
Panel
- Panel
- Plasterboard Slots
- Perforation
- Slots
- Open area
- 13.1 %
- Panel thickness
- 12.9 mm
- Scrim
- Yes
- Orientation
- Standard
Insulation
- Insulation
- Glass wool
- Thickness
- 100 mm
- Thermal R-value
- R5
- Flow resistivity σ
- 9.6k N·s/m⁴measured 9.3k–9.8k
- Flow resistance σ·d
- 957 N·s/m³
Mass-loaded vinyl
- MLV
- No
Test
- Tested
- 10 July 2026
- Matrix group
- Impact on Hole Shape & Other Variables
Band values
| Hz | R | Ref. | Dev. | T60 | αs |
|---|---|---|---|---|---|
| 50 | – | – | – | ||
| 63 | 15.8 | 15.82 | – | ||
| 80 | 11.4 | 7.70 | – | ||
| 100 | 14.3 | -1 | 0.0 | 6.81 | 0.52 |
| 125 | 13.7 | 2 | 0.0 | 5.45 | 1.53 |
| 160 | 11.2 | 5 | 0.0 | 6.05 | 1.31 |
| 200 | 10.3 | 8 | 0.0 | 4.90 | 1.49 |
| 250 | 10.9 | 11 | 0.1 | 4.51 | 1.56 |
| 315 | 11.6 | 14 | 2.4 | 4.19 | 1.81 |
| 400 | 12.3 | 17 | 4.8 | 4.08 | 1.44 |
| 500 | 13.3 | 18 | 4.8 | 4.40 | 1.50 |
| 630 | 14.6 | 19 | 4.4 | 4.39 | 1.49 |
| 800 | 15.9 | 20 | 4.1 | 4.36 | 1.45 |
| 1k | 17.1 | 21 | 3.9 | 3.96 | 1.39 |
| 1.25k | 18.4 | 22 | 3.6 | 3.65 | 1.30 |
| 1.6k | 19.6 | 22 | 2.4 | 3.41 | 1.32 |
| 2k | 20.9 | 22 | 1.1 | 3.07 | 1.53 |
| 2.5k | 22.4 | 22 | 0.0 | 2.84 | 1.46 |
| 3.15k | 23.1 | 22 | 0.0 | 2.55 | 1.56 |
| 4k | 24.1 | 2.19 | 1.88 | ||
| 5k | 24.4 | 1.77 | 2.12 | ||
| 6.3k | 25.1 | 1.42 | – | ||
| 8k | 26.6 | 1.12 | – | ||
| 10k | 27.8 | 0.88 | – | ||
| Σ | 31.5 |
R, Ref. and Dev. in dB, T60 in s. Ref. is the ISO 717-1 reference curve shifted to Rw 18 dB; Dev. is how far R falls below it, and the deviations may total at most 32 dB. αs over 100 Hz–5 kHz only.
In comparisons4
Sets of tests that differ from this one in a single variable.
Effect of insulation
Plasterboard Slots, No MLV
This testGW 100 mm R5Rw rank4 of 6
Effect of hole shape
Plasterboard, Glass Wool 100 mm R5, No MLV
This testPB Slots (13.1%)Rw rank1 of 5
Effect of flow resistivity
Plasterboard Slots, No MLV
This testGW 100 mm R5 (9,600 N·s/m⁴)Rw rank4 of 6
Effect of open area
Plasterboard, Glass Wool 100 mm R5, No MLV
This testPB Slots (13.1%)Rw rank1 of 5