PB Slots + GW 90 mm R2.7
Plasterboard Slots · Glass Wool 90 mm R2.7 · No MLV
Tested 10 July 2026
Rw (C; Ctr)
25dB
C 0 · Ctr −3
ΔRw vs open
+25dB
Fit to R − R(open aperture)
Mean R
24.2dB
100–3150 Hz
Rank by Rw
12of 64
Tied with 3 others
Specification
Panel
- Panel
- Plasterboard Slots
- Perforation
- Slots
- Open area
- 13.1 %
- Panel thickness
- 12.9 mm
- Scrim
- Yes
- Orientation
- Standard
Insulation
- Insulation
- Glass wool
- Thickness
- 90 mm
- Thermal R-value
- R2.7
- Flow resistivity σ
- 26.4k N·s/m⁴measured 19.7k–33.7k
- Flow resistance σ·d
- 2.4k N·s/m³
Mass-loaded vinyl
- MLV
- No
Test
- Tested
- 10 July 2026
- Matrix group
- Impact on Hole Shape & Other Variables
Band values
| Hz | R | Ref. | Dev. | T60 | αs |
|---|---|---|---|---|---|
| 50 | – | – | – | ||
| 63 | 17.3 | 14.80 | – | ||
| 80 | 13.3 | 8.07 | – | ||
| 100 | 16.9 | 6 | 0.0 | 7.06 | 0.36 |
| 125 | 16.1 | 9 | 0.0 | 5.82 | 1.16 |
| 160 | 14.2 | 12 | 0.0 | 6.30 | 1.10 |
| 200 | 13.7 | 15 | 1.3 | 5.08 | 1.26 |
| 250 | 14.9 | 18 | 3.1 | 4.68 | 1.31 |
| 315 | 16.6 | 21 | 4.4 | 4.34 | 1.55 |
| 400 | 18.4 | 24 | 5.6 | 4.14 | 1.33 |
| 500 | 20.4 | 25 | 4.6 | 4.48 | 1.37 |
| 630 | 22.6 | 26 | 3.4 | 4.40 | 1.47 |
| 800 | 25.1 | 27 | 1.9 | 4.36 | 1.45 |
| 1k | 27.6 | 28 | 0.4 | 3.95 | 1.41 |
| 1.25k | 30.6 | 29 | 0.0 | 3.63 | 1.35 |
| 1.6k | 33.3 | 29 | 0.0 | 3.43 | 1.27 |
| 2k | 36.3 | 29 | 0.0 | 3.11 | 1.40 |
| 2.5k | 39.3 | 29 | 0.0 | 2.83 | 1.50 |
| 3.15k | 41.6 | 29 | 0.0 | 2.57 | 1.47 |
| 4k | 44.4 | 2.20 | 1.81 | ||
| 5k | 46.4 | 1.77 | 2.12 | ||
| 6.3k | 49.0 | 1.42 | – | ||
| 8k | 52.8 | 1.12 | – | ||
| 10k | 55.5 | 0.89 | – | ||
| Σ | 25.0 |
R, Ref. and Dev. in dB, T60 in s. Ref. is the ISO 717-1 reference curve shifted to Rw 25 dB; Dev. is how far R falls below it, and the deviations may total at most 32 dB. αs over 100 Hz–5 kHz only.
In comparisons4
Sets of tests that differ from this one in a single variable.
Effect of insulation
Plasterboard Slots, No MLV
This testGW 90 mm R2.7Rw rank1 of 6
Effect of hole shape
Plasterboard, Glass Wool 90 mm R2.7, No MLV
This testPB Slots (13.1%)Rw rank2 of 5
Effect of flow resistivity
Plasterboard Slots, No MLV
This testGW 90 mm R2.7 (26,400 N·s/m⁴)Rw rank1 of 6
Effect of open area
Plasterboard, Glass Wool 90 mm R2.7, No MLV
This testPB Slots (13.1%)Rw rank2 of 5